RECOM 3 SE EPP FPD EC Enthalpy Air Handling Unit
Compact enthalpy heat recovery unit in EPP casing with flexible control
Enjoy silence and fresh air in your home without any hassle. RECOM 3 SE EPP EC ensures efficient ventilation with moisture recovery, quiet operation thanks to the insulated EPP casing, and extremely easy wall or floor mounting.
Silence — just 37 dB(A)
Quieter than a typical fridge — ideal for placement near living spaces.
Lightweight EPP casing — 22 kg
Polypropylene casing is exceptionally light, absorbs sound, and eliminates thermal bridges.
Moisture recovery — up to 84%
Enthalpy heat exchanger maintains indoor humidity in winter, protecting wooden floors and furniture.
Why choose RECOM 3 SE EPP EC?
Imagine a home where it is always fresh, but you never hear the hum of a ventilation system. The RECOM 3 SE EPP EC wall-mounted unit is designed for exactly this kind of comfort. Thanks to its special lightweight and sound-insulating EPP (expanded polypropylene) casing, the unit operates at just 37 dB(A). It is perfect for medium-sized spaces, supplying up to 304 m³/h of fresh air.
This unit features an enthalpy heat exchanger, which recovers not only heat (up to 84%) but also valuable indoor moisture during winter. This means your skin won't dry out, wooden floors are protected, and the air feels naturally fresh. The A energy class and EC motors ensure your energy bills stay minimal.
Smart or basic control — choose what fits your needs
Both models utilize the same efficient ventilation technology but allow you to select the level of control that suits you best.
FPD (WiFi) — maximum convenience and automation
By choosing the FPD version, you get an integrated Wi-Fi module. Control your ventilation via the smartphone app from anywhere. Additionally, this version features a factory-integrated 1.4 kW pre-heater, ensuring flawless operation even on the coldest winter nights.
FP — reliable classic
The FP version is ideal for those who value simplicity. The system is reliably controlled via a wired wall panel. Because this version does not have an integrated pre-heater, an external one can be added to the ductwork if needed.
Complete ventilation system with REC BalticVent
The right air handling unit is just the heart of the system. For flawless operation, pair it with flexible ducts, silencers, and high-quality diffusers. The ORO Haus team is always ready to help you configure your complete setup from A to Z.
| Which to choose? | FPD (WiFi) | FP |
|---|---|---|
| Purpose | Smart homes | Standard ventilation |
| Wi-Fi control | Integrated | None |
| Display | Touch LCD | Basic |
| Pre-heater | Integrated (1.4 kW) | External (ordered separately) |
| Max power | 1576 W | 176 W (without heater) |
| Price | Higher | Lower |
Key "RECOM 3 SE EPP EC" specifications
These technical parameters will help you evaluate the unit's capacity and suitability for your home. Both versions deliver exceptional performance.
| Specification | FPD (WiFi) | FP |
|---|---|---|
| Max. airflow | 304 m³/h | 304 m³/h |
| Heat recovery efficiency | 84% | 84% |
| Noise level (at 3 m) | 37 dB(A) | 37 dB(A) |
| Energy class | A | A |
| Heat exchanger type | Enthalpy (moisture recovery) | Enthalpy (moisture recovery) |
| Supply voltage | 230V / 50-60 Hz | 230V / 50-60 Hz |
| Max. power (without heater) | 176 W | 176 W |
| Max. total power | 1576 W (with integrated 1400W heater) | 176 W (external heater only) |
"RECOM 3 SE EPP EC" dimensions and weight
The ultra-lightweight EPP casing allows for physically undemanding installation, while universal dimensions suit wall or floor mounting.
| Parameter | FPD (WiFi) | FP |
|---|---|---|
| Height | 852 mm | 852 mm |
| Width | 600 mm | 600 mm |
| Depth | 419 mm | 419 mm |
| Weight | 22 kg | 22 kg |
| Duct connections | Ø 125 mm | Ø 125 mm |
| Insulation thickness | 25 mm | 25 mm |
"RECOM 3 SE EPP EC" features and capabilities
Familiarize yourself with the smart features of the unit that facilitate daily use and ensure longevity.
| Feature | FPD (WiFi) | FP |
|---|---|---|
| Bypass mode | Yes (Auto, manual) | Yes (Manual) |
| Summer cooling | Yes | Yes |
| Frost protection | Yes (Integrated heater) | Yes (Supply fan shutdown) |
| Filters (included) | G4 (supply) / G4 (extract) | G4 (supply) / G4 (extract) |
| Control | Wi-Fi (Blauberg Home app) + LCD panel | Wired wall panel |
| Filter replacement indication | Yes (timer) | Yes (timer) |
| Weekly schedule | Yes | No |
| Supported sensors (optional) | CO₂, RH%, VOC, PM2.5 | CO₂, RH%, VOC, PM2.5 |
| Fire alarm sensor connection | Yes | Yes |
Proper installation of the unit guarantees long-term, quiet, and efficient operation. This model can be wall-mounted or floor-mounted. The full manufacturer's manual can be found in the specifications tab.
What is in the box
The manufacturer's package includes the essential system elements:
- Fully assembled RECOM 3 SE EPP EC unit
- Set of G4 filters
- Control panel (FPD or FP version depending on selection)
- User and installation manual
What you will need additionally
For a successful installation, we recommend securing the following accessories:
- Mounting hardware suitable for wall or floor structure
- Vibration isolation pads for quiet operation [NOT IN PDF]
- Power supply cable
- Flexible connectors and ductwork components
Dimensions and location selection
The unit is designed for wall and floor mounting. A minimum free space of 1 meter must be left in front of the unit for service and filter replacement. The installation location must be protected from direct sunlight and freezing temperatures.
Duct connection
All ducts on the unit have a standard Ø 125 mm diameter. The unit can be of left (L) or right (R) design – pay attention when connecting supply, extract, intake, and exhaust air ducts. To prevent vibration, it is recommended to connect the ducts via flexible connectors.
Condensate drainage
Because the RECOM 3 SE model features an enthalpy (moisture recovery) heat exchanger, condensation inside the unit is less frequent. However, depending on indoor humidity and external temperatures, the need for a condensate drain must be evaluated according to manufacturer instructions.
Electrical connection
Electrical work must only be performed by a qualified electrician. The unit connects to a single-phase 230V power network. Proper grounding and a dedicated circuit breaker are required.
Control systems
Control automation is integrated in FPD units. The Blauberg Home app allows full Wi-Fi configuration. In the FP version, the wired wall panel connects to the designated terminals in the unit. External sensors like CO₂, humidity, and fire alarms can also be connected.
First start
Before turning on the system, perform the following steps:
- Check that the G4 filters are correctly installed in their places.
- Ensure all duct connections are sealed tight.
- Verify the correctness of the electrical connection.
- Turn on the unit and balance the airflows at the diffusers.
Maintenance and filters
For smooth operation, regularly replace the G4 (and optional F7) air filters when notified by the system timer. It is recommended to vacuum the enthalpy heat exchanger and inspect the fans annually. If you have questions about installation, the ORO Haus team is ready to help.

Build your ventilation system with RECOM 3 SE EPP EC
The heat recovery unit is just the beginning — add high-quality ducts, silencers, and diffusers for a quiet and efficient system. ORO Haus will help you configure everything in one place.
Frequently Asked Questions
Reviews
Be the first to review!
This product doesn't have any reviews yet. Share your experience.