RECOM 2 SET EPP EC Enthalpy Heat Recovery Unit
Compact and lightweight ceiling-mounted air handling unit in EPP casing
Ensure continuous fresh air in your home without any noise. The RECOM 2 EPP series air handling units feature an ultra-lightweight EPP casing that guarantees excellent thermal and sound insulation as well as easy installation. Weighing just 15 kg and delivering up to 181 m3/h airflow, this compact unit is ideal for apartments and small houses.
Quiet operation - 33 dB(A)
The innovative EPP casing dampens sound, ensuring the unit operates discreetly without disturbing your peace.
Ultra-lightweight EPP casing
Weighing only 15 kg, the expanded polypropylene unit greatly simplifies ceiling installation and perfectly insulates heat.
Smart control
The option to choose the FPD controller with integrated Wi-Fi allows convenient system management directly from your smartphone.
Why choose RECOM 2 ST/SET EPP EC?
Enjoy pure and fresh air in your home without any compromises. The RECOM 2 series is designed with modern compact homes in mind, where every centimeter counts. Made from innovative EPP (expanded polypropylene) material, this air handling unit is exceptionally lightweight, weighing just 15 kg, making ceiling installation quick and straightforward. The material properties also guarantee top-tier thermal and sound insulation, allowing the EC motors to operate at a whisper-quiet 33 dB(A).
Enthalpy or condensing heat exchanger?
This model allows you to choose the heat exchanger type that best suits your needs. The SET version with an enthalpy heat exchanger is an ideal choice for cold climates, as it returns moisture back into the rooms during winter, preventing unpleasant air dryness and eliminating the need for drainage. The ST version with a standard plate heat exchanger offers maximum energy efficiency (A+ class) and flawless heat recovery for those aiming for absolute energy savings.
Complete ventilation system with RECOM
The unit is compatible with all standard 160 mm ducts. By choosing the FPD setup with integrated Wi-Fi, the system becomes part of your smart home, controlled via a simple app. Contact ORO Haus specialists, and we will help you assemble all necessary ducts, diffusers, and accessories for a perfectly functioning system.
| Which to choose? | Enthalpy (SET) | Plate (ST) |
|---|---|---|
| Purpose | Optimal moisture balance in winter | Maximum heat savings |
| Heat recovery | Up to 81% | Up to 90% |
| Energy class | A | A+ |
| Moisture recovery | Yes | No |
| Condensate drainage | Usually not required | Required |
Key RECOM 2 EPP EC specifications
Despite its ultra-compact dimensions and lightweight EPP casing, this unit delivers up to 181 m3/h airflow, easily providing fresh air for small homes or apartments while consuming very little electricity.
| Specification | Enthalpy (SET) | Plate (ST) |
|---|---|---|
| Max. airflow | 181 m3/h | 181 m3/h |
| Heat recovery efficiency | 81% | 90% |
| Noise level | 33 dB(A) | 33 dB(A) |
| Energy class | A | A+ |
| Max. power consumption | 53 W | 53 W |
| Duct diameter | 160 mm | 160 mm |
Dimensions and weight
The extremely lightweight EPP casing, weighing just 15 kg, ensures that lifting and securing the unit to the ceiling is hassle-free for a single installer.
| Parameter | Enthalpy (SET) | Plate (ST) |
|---|---|---|
| Weight | 15 kg | 15 kg |
| Duct connection diameter | 160 mm | 160 mm |
Features and capabilities
Advanced unit automation offers all the protection and comfort features required for a modern system.
| Feature | Enthalpy (SET) | Plate (ST) |
|---|---|---|
| Casing material | EPP (expanded polypropylene) | EPP (expanded polypropylene) |
| Bypass mode | Yes | Yes |
| Motor type | EC (electronically commutated) | EC (electronically commutated) |
| Condensate drainage | Usually not required | Required |
| Control | FPD (Wi-Fi + display) or FP (basic) | FPD (Wi-Fi + display) or FP (basic) |
The RECOM 2 EPP EC model is designed for ceiling mounting. Its EPP casing makes it exceptionally lightweight, but it is important to follow all installation instructions for rooms where the ambient temperature ranges from +1°C to +40°C. You can download the full manufacturer manual in PDF format in the specifications section of this page.
What is in the box
The manufacturer's package includes:
- Fully assembled air handling unit in EPP casing
- Selected controller (FPD or FP)
- Filters pre-installed in the unit
- User manual
What you will need additionally
These items are not included and must be purchased separately:
- Threaded rods with nuts for ceiling mounting
- Vibration isolation pads to ensure maximum silence
- Electrical power cable
- 160 mm ductwork system elements and flexible connectors
Dimensions and location selection
To prevent condensation on the inner walls of the unit, ensure proper conditions in the room. Leave sufficient clearance below the unit for easy filter replacement and maintenance.
Duct connection
The unit uses 160 mm diameter connections. To prevent vibration transmission to the ductwork and ensure quieter system operation, we recommend using flexible connectors (silencers).
Condensate drainage
For the plate (ST) model, condensate drainage is mandatory, requiring a proper siphon installation. For the enthalpy (SET) model, condensate drainage is usually not required under normal residential conditions, but may be planned as a precaution in highly humid environments.
Electrical connection
Electrical connections must only be performed by a qualified electrician according to the provided diagram. The unit is classified as a Class I electrical appliance and requires proper grounding.
Control systems
By connecting the FPD controller, you can activate the integrated Wi-Fi. This allows you to control fan speeds, monitor temperatures, and receive filter replacement notifications directly on your smartphone.
First start
Before the first power-on:
- Check that the unit is free of installation dust and filters are correctly seated.
- Ensure that the ducts are sealed and secured.
- Turn on the unit and perform initial airflow balancing via the control panel.
Maintenance and filters
Regularly inspect and replace filters, especially after new building construction. Do not operate the unit without filters, as dust can damage sensitive heat exchanger and EC motor components.

Build your complete ventilation system with RECOM 2 EPP
Add flexible ducts, distribution boxes, and diffusers. Buying the entire system at once ensures 100% component compatibility and optimal performance.
Frequently Asked Questions
Reviews
Be the first to review!
This product doesn't have any reviews yet. Share your experience.